OCU - 3200S

Cooling power:2800/3200W
Voltage:Three-phase AC 220/380V
Installation method:
Dimensions:H775xW360xD440mm
Weight:56kg

Specifications Installing the dimensional

Model OCU-3200S
Cooling Method Air-Cooled type
Performance Cooling Capacity          [W] 1300/1400
Usable Oil Types Lube Oil , Hydraulic Mineral Oil
Oil Viscosity        [mm2/s] 1.4~200 (ISO GV2~32)
Tenperature adjust (Selectable) Tuning Form Setting Criteria Room temperature, Body temperature
Control Targe Inlet oil temperature, Outlet oil temperature
Tuning Range [℃] For setting the reference temperature, -19.9 ~ 19.9
Non-removable Type Control Target Inlet oil temperature, Outlet oil temperature
Control Range[℃] 5~50
Use Area temperature             [℃] 5~45
Inlet Oil temperature             [℃] 5~50
Electrical characteristics Rated Voltage                   [V] 3AC  220/380V  50Hz
Power consumption            [W] 1430
Consumption Current         [A] 4.6
Transformer capacity        [kVA] 2.6
Components Compressor Swing Type
Condenser Cross-fin Type
Evaporator Shell-end coil Type
Fan Rated output          [W] 54
Oil Pump Rated output         [kW] 0.4
Oil pump flow rate  [L/min] 24/28.8
Opening pressure  [Mpa] 0.6
Refrigerant control Compressor revolutions by inverter + Opening of electric expansion valve
Refrigerant R410A
Oil temperature sensor Thermistor
Connecting tube Oil inlet    [RC] RC3/4
Oil outlet   [RC] RC3/4
Oil drain    [RC] RC1/4(Plugged)
Safety Circuit Compressor Temperature protector, Overcurrent relay
Refrigeration Cycle High pressure switch
Pump Overcurrent relay, Relief valve
Circuit Board Fuse
Input-Output Alarm Output Equipment abnormalities, Condensing temperature anomaly
Control input Remote operation
External Thermista 2W (Optional)
RS-232C RS-232C
Noise                                  [dB] 65
Ingress protection                       [IP] IP2X
External Dimensions(H×W×D)              [mm] 775x360x440
Weight                        [kg] 56

Notes1.The cooling capacity represents the value at the standard point(inlet oil temperature:35,room temperature35,oil for use:ISO VG32).

2. Be sure to use a commercial power supply for the power source.The use of an inverter power supply may cause burn damage to the unit.

3. The yellow line on the tank oil level gauge shows the highest oil level and the red line the lowest oil level.


contact us

Electenergy Technology&Innovation(Shenzhen)Co.,Ltd.
Add:RM.32A,Haijing Square,Taizi Road,Shekou,Nanshan District,Shenzhen,China.
TEL: +86-755-2649 7123    FAX: +86-755-26497124
Email: ray@eticn.com
Shanghai office
Add:Rm208,BLD 5,Jiangqiao Wanda Plaza,Block 26,Hexuan Road,Jiading District,Shanghai.
TEL: +86-755-2649 7123    FAX: +86-755-26497124
Email: ray@eticn.com